Certified, with in-house engineering
We are a certified integrator in Inductive Automation's Integrator Program. The team that scopes your project is the team that builds and supports it.
Certified Ignition integrator
Ignition runs plants as SCADA and buildings as their BMS. We supply the licences, build the screens, history and alarms, and support it, from a single panel to a fleet of sites. And because we also build the Volts platform, the data can carry on to energy reports, tenant charges and AI agents when you need it.
Please enter a valid email address.
by Inductive Automation
140+
countries with Ignition installations
69%
of Fortune 100 companies use Ignition
2003
Inductive Automation founded
Figures published by Inductive Automation, September 2026.
Why Ignition
Classic SCADA and BMS software is often priced per tag or point, installed workstation by workstation and tied to its own historian. Ignition, from Inductive Automation, takes the opposite approach on all three.
Licensing
One Ignition Standard licence covers a server, with unlimited tags, device connections, screens and clients. More tags, screens or operators do not change the price.
Build and run
Engineers build screens, tags, alarms and scripts in one Designer. The gateway serves the result to control-room desktops, panels, browsers and phones.
Open by design
Core drivers for Siemens, Allen-Bradley, Modbus, BACnet, DNP3, Omron, Mitsubishi and IEC 61850, plus OPC UA and MQTT, so equipment from different vendors meets on one system.
Ignition as a BMS
The platform that runs a production line can be a building's BMS: plant graphics, schedules, setpoints, alarms and trends for heating, cooling, ventilation and lighting. It talks BACnet and Modbus to the controllers already in the building, so a closed BMS front end can be replaced without replacing the field.
Before
After
The BACnet and Modbus controllers, sensors, valves and drives already in the building. Control loops stay in them, and MS/TP networks connect through a BACnet router.
Happy with the BMS you have? Ignition can work next to it instead, finish what it never did and leave every writable point with one owner.
From one panel to a fleet
Ignition Edge runs on a panel or small PC at each site. A central Ignition Standard gateway brings every site together, and the Enterprise Administration Module backs them up and upgrades them from one place. We size each site to the smallest edition that does the job.
When we recommend Standard over Edge: more than two people need live screens at the same time, the site needs its own database, transaction groups or reports, or one gateway has to run several projects.
Ignition + Volts
SCADA data rarely leaves the control room. Follow one reading from the plant floor to the monthly report.
On the plant floor
PLCs, BMS controllers and meters already measure the plant. Ignition reads them over OPC UA, Modbus, BACnet or the vendor's own protocol.
On the operator's screen
Operators see it live, the historian keeps every value, and the right person is called when it drifts. Control stays on site, with or without an internet connection.
In the monthly report
Over MQTT, the same reading reaches Volts: energy and ESG reports, tenant charges, maintenance work orders and AI agents that act only where you allow it.
Ignition works on its own. Volts is there when the data needs to leave the control room, and every writable point has one owner, agreed before commissioning.
See building automation in VoltsWhy work with us
SCADA projects usually stop at the control room. We are certified on Ignition and we build Volts, so the same plant data can go on to the people who pay the bills, report the energy and fix the equipment.
We are a certified integrator in Inductive Automation's Integrator Program. The team that scopes your project is the team that builds and supports it.
Ignition runs the site in real time. Volts, which we also build, carries the same data to energy reports, tenant charges, maintenance and AI agents. One team owns the line between them.
Process lines and building services both, from PLCs and BMS to meters on Modbus, M-Bus and BACnet. Where a signal is missing, we add a meter or relay we design and make ourselves.
Where a BMS or SCADA was bought and never fully used, we complete the scope over Ignition instead of replacing what already works.
Ignition Edge where it is enough, Standard where the site needs it. Each proposal names the reason, so you buy the licence the site requires and nothing more.
Before commissioning, every writable point gets exactly one owner, so Ignition, the BMS and Volts do not fight over the same setpoint.
What we deliver
Take one service or the full project. Each scope states what we deliver, what you receive and what stays with your team.
Edition, modules, servers, redundancy and network security, sized to the site. We supply the licences as part of the project.
Overviews, faceplates and operator screens in Perspective for browsers and phones, or Vision for control-room desktops, built on reusable templates.
PLCs, drives, meters, BMS and legacy systems, connected through Ignition's drivers, OPC UA or MQTT and organised into reusable data types.
Process history, trends, scheduled PDF reports and KPI dashboards, kept in a historian or SQL database your IT team can back up and query.
Alarm pipelines, on-call rosters and escalation by email, SMS or voice call, so each alarm reaches someone who can act on it.
OEE, downtime reasons, counts, recipes and batch records, collected from the line and written to the database the business reports from.
Ignition Edge at remote or unmanned sites, store-and-forward buffering, MQTT to a central gateway, and EAM to back up and upgrade every gateway from one place.
Replace a legacy SCADA, HMI or BMS front end area by area, running side by side until each one is signed off, or upgrade an existing Ignition system to 8.3.
Support agreements, remote and on-site help, operator and engineer training, and documentation your team can work from.
Already running Ignition? We also audit, document and take over systems built by someone else. Tell us about your gateway
How a project runs
Each phase ends with something your team can inspect and sign off before the next one starts.
1. Audit the site
2. Design and quote
3. Build and test off site
4. Commission, loop by loop
5. Support and grow
FAQ
Yes. We are a certified integrator in Inductive Automation's Integrator Program, and the Ignition engineering on your project is done by our own team. We share the current certification details at scoping.
No. An Ignition project with us is a standard Ignition system that runs on its own. Volts is an option for when the same data needs to reach energy, finance or property teams.
Yes. We quote the licences with the project, sized to the edition and modules the site needs. Standard and Edge licences are one-time purchases, with optional annual support plans from Inductive Automation.
Edge suits a single machine, panel or small site. Standard suits a plant, a campus or a central gateway for many sites. Where Edge is enough we start there, and the proposal names the trigger that would justify Standard.
Yes. Ignition can be the building's BMS: plant graphics, schedules, setpoints, alarms and trends, talking BACnet and Modbus to the controllers. Where the field controllers are sound they stay, and only the front end changes. Control loops stay in the controllers, and every writable point has one owner.
Usually, yes. Ignition has drivers for Siemens, Allen-Bradley, Modbus, BACnet and other common protocols, and connects to OPC UA servers. The audit tests representative connections before the scope is priced.
Yes. We audit the gateway and its projects, document what is there, fix what is risky and take over support, including upgrades to Ignition 8.3.
Ignition runs on site, so local screens, alarms and control carry on. Ignition Edge buffers up to 35 days of data and forwards it when the link returns, so central history and Volts reports catch up.
You do. The licence is yours, and the project is a standard Ignition project, documented at handover, so your own engineers or another Ignition integrator can maintain it.
Yes. Ignition is free to download and runs with every feature in a two-hour trial that can be reset as often as needed. We can build a proof of concept on the trial before any licence is bought.
Share the controllers, BMS or SCADA you run today and what you need Ignition to do. We will tell you which edition and modules fit, what can stay and how the first site would be built.